60mm industrial stainless steel pressure gauge

A compact dial with the mounting style your equipment needs

Choose a 60 mm stainless steel pressure gauge with a bottom connection or a flanged back connection for local pressure readings on industrial equipment. Match the wetted materials and pressure scale to your process. A larger 100 mm vibration-resistant model is also available when your installation has room for a bigger dial.

Choose the mounting style for your 60 mm gauge

The Y-60BF connects below the dial, while the Y-60BFZT connects behind it and includes a mounting flange. The bottom connection suits a pressure point approached from below. The back connection routes the line behind the dial, and the flange provides a way to secure the gauge to a panel.

A nominal 60 mm dial is about 2.36 inches across. A U.S. 2.5-inch dial is about 63.5 mm, so an existing 2.5-inch gauge may have a different footprint. For a panel replacement, compare the case diameter, panel opening, flange hole spacing, and clearance behind the panel; dial size alone does not establish fit.

NPT, BSP, and metric thread options belong to different connection systems. Specify the full thread designation and sealing arrangement for the equipment port so the connection fits without forcing a mismatched thread.

Stainless steel where it meets the process

The process connection and Bourdon tube carry the measured fluid. Pressure flexes the tube, and a mechanical movement transfers that motion to the pointer. The stainless steel case protects the mechanism from the surrounding environment; fluid compatibility depends on the parts inside the pressure path.

These gauges serve compatible gases and liquids, including industrial processes where corrosion resistance is needed. Select the wetted material for the actual fluid, concentration, and temperature. If your process requires 316 stainless steel, specify it for the connection and Bourdon tube, along with compatible seals.

A direct pressure passage works best with media that flow freely through it. Viscous liquids, crystals, or suspended solids can obstruct that passage. A diaphragm-seal arrangement separates such media from the gauge’s internal pressure path and should be evaluated for those conditions.

Compare the three available models

Two models cover the 60 mm mounting choices. The third provides a larger, vibration-resistant alternative with a 100 mm dial.

Y-60BFZT 60 mm stainless steel pressure gauge with axial connection and mounting flange
60 mm dial with flanged back connection.

Stainless Steel Pressure Gauge Y-60BFZT

A 60 mm gauge with a back connection and mounting flange for installations that route the pressure line behind the dial. The flange secures the gauge to a panel while keeping the dial visible from the front.

  • Nominal dial diameter60 mm
  • Connection layoutaxial, with flange
  • Casestainless steel
  • Ambient operating temperature−4 to 140°F (−20 to 60°C)
  • Maximum media temperature140°F (60°C)
Y-60BF 60 mm stainless steel pressure gauge with radial connection
60 mm dial with bottom connection.

Stainless Steel Pressure Gauge Y-60BF

A 60 mm gauge with a radial connection below the dial for local pressure indication where the process line approaches from underneath. This layout keeps the connection accessible below the case.

  • Nominal dial diameter60 mm
  • Connection layoutradial, below the dial
  • Casestainless steel
  • Ambient operating temperature−4 to 140°F (−20 to 60°C)
  • Maximum media temperature140°F (60°C)
YN-100BFZT 100 mm stainless steel vibration-resistant pressure gauge with axial connection and mounting flange
100 mm vibration-resistant model with flanged back connection.

Stainless Steel Vibration-Resistant Pressure Gauge YN-100BFZT

A 100 mm gauge with an axial connection and flange for vibration-prone installations. Its larger dial gives the scale more space for local viewing and requires a larger installation footprint than the two 60 mm models.

  • Nominal dial diameter100 mm, approximately 4 inches
  • Connection layoutaxial, with flange
  • Designstainless steel, vibration-resistant
  • Ambient operating temperature−4 to 140°F (−20 to 60°C)
  • Maximum media temperature140°F (60°C)

Match the scale to the pressure you need to read

Choose the scale from the normal operating pressure and the pressures reached during startup, shutdown, and process changes. A scale that is too low leaves insufficient room for peaks. An unnecessarily wide scale compresses the operating region into a smaller part of the dial, making small changes harder to read.

Accuracy expressed as a percentage of full scale also changes with the selected range. For example, 2.5% of a 150 psi full scale is 3.75 psi. That calculation explains an accuracy specification; it does not describe the smallest dial division or a percentage of the current reading.

Include your normal pressure, expected peak pressure, preferred units, and required accuracy when requesting a quote. These define the scale and performance needed for the application.

Keep the pointer readable around vibration and heat

Liquid filling damps movement inside the case, helping steady the pointer where equipment vibration makes a dry gauge difficult to read. Glycerin and silicone oil are filling options for the flanged 60 mm product family. Select the fill with the operating temperature in mind.

Pressure pulsation reaches the gauge through the process line. A suitable snubber or restrictor can reduce that changing pressure load before it reaches the sensing element. For a pump installation, the choice therefore depends on both vibration at the mounting point and pressure changes in the line.

The ambient operating range for these models is −4 to 140°F (−20 to 60°C), with a maximum media temperature of 140°F (60°C). For hotter process lines, evaluate a cooling arrangement or remote mounting that keeps the gauge within those limits. Steam service requires a suitable siphon or other engineered thermal isolation.

Request a Quote for Your Gauge Configuration

Contact Hangzhou Dongya Instrument Co., Ltd. for help selecting a model and preparing a quote. In the Requirement field, describe the process fluid and operating pressure, then add the mounting style, thread, and quantity you need. For a replacement, include the existing gauge model or its installation dimensions.

Contact information

WhatsApp QR Code WhatsApp Chat
+86-18968133688