glycerine filled pressure gauge

Mechanical pressure gauges for vibration and pulsation

Keep the pointer readable on pumps, compressors, hydraulic equipment, and other installations where vibration or pressure cycling makes a dry gauge difficult to read. Hangzhou Dongya Instrument Co., Ltd. supplies liquid-filled gauges with glycerin or silicone oil, plus multiple dial sizes, mounting styles, pressure ranges, connection threads, and material options.

Steadier readings where vibration moves the pointer

A liquid-filled mechanical gauge uses a Bourdon tube to sense process pressure and a linkage and gear movement to position the pointer. Glycerin surrounds the movement inside the case. Its viscous resistance damps the rapid motion caused by equipment vibration, pressure pulsation, and repeated starts and stops.

The damping makes the pointer easier to read and reduces repeated impact on the movement. The fill also limits the air volume around the movement, which can reduce internal condensation when the case and venting design are suitable for the environment. Glycerin remains inside the case during normal service; it does not become the process fluid or change the pressure range.

Liquid fill does not create a higher accuracy class by itself. Accuracy comes from the sensing element, movement, calibration, temperature behavior, and the specification of the finished gauge. The practical gain is a steadier indication under dynamic conditions and less mechanical wear from constant pointer oscillation.

Compare Available Gauges

Choose the connection that fits the panel or pipe

ConfigurationBest fitInstallation detail to confirm
4-inch axial rear connection with front flangeControl panels and machine faces where the dial must be visible from the frontPanel cutout, flange-hole pattern, depth behind the panel, and rear thread
4-inch lower radial connectionPipework and equipment ports with room above the connectionThread standard, wrench clearance, viewing direction, and vibration support
2.5-inch lower radial connectionCompact equipment and crowded piping where a smaller dial is preferredReading distance, thread size, pressure range, and available clearance

Glycerin is a common choice for general industrial temperatures. Its viscosity can increase in cold conditions and slow pointer response. Silicone oil may be the better fill when the installation has a wider temperature swing or lower ambient temperature. Specify the fill in the order rather than treating all liquid-filled gauges as the same configuration.

Get Selection Help

Glycerine-filled pressure gauge options

The three product pages below list glycerin and silicone oil as fill options. State glycerin fill in your RFQ when that is the required configuration.

Front view of the YN-100ZT liquid-filled pressure gauge with a circular front flange, three mounting holes, and dual MPa and psi scale.

Liquid Filled Pressure Gauge 4 Inch Axial Direction With Flange

This 4-inch gauge uses an axial rear connection and a circular front flange for panel installation. It combines a large dial with liquid damping for machinery and pressure systems subject to vibration or pulsation.

  • Nominal dial size4 in class (100 mm nominal)
  • Mountingaxial rear connection with front flange
  • Accuracy class1.6
  • Fill options listed on the product pageglycerin or silicone oil
  • Ingress protection listed on the product pageIP54
  • Operating temperature listed on the product page-4°F to 140°F (-20°C to 60°C)
  • Maximum media temperature listed on the product page140°F (60°C)
  • Confirm for ordered configurationPressure range, process thread, wetted materials, case material, and flange dimensions
Front view of the YN-100 liquid-filled pressure gauge with a lower process connection and dual MPa and psi scale.

Liquid Filled Pressure Gauge 4 Inch Radial Direction

This 4-inch lower-mount gauge connects beneath the case for direct installation on pipework, manifolds, and equipment ports. The liquid-filled case steadies the pointer where machine vibration or pressure cycling would keep a dry pointer in motion.

  • Nominal dial size4 in class (100 mm nominal)
  • Mountinglower radial connection
  • Accuracy class1.6
  • Fill options listed on the product pageglycerin or silicone oil
  • Ingress protection listed on the product pageIP54
  • Operating temperature listed on the product page-4°F to 140°F (-20°C to 60°C)
  • Maximum media temperature listed on the product page140°F (60°C)
  • Confirm for ordered configurationPressure range, process thread, wetted materials, and case material
Front view of a compact 2.5-inch liquid-filled pressure gauge with a lower process connection and dual MPa and psi scale.

Liquid Filled Pressure Gauge 2.5 Inch Radial Direction

This compact lower-mount gauge provides liquid damping in a 2.5-inch nominal dial format. It fits machinery and piping where installation space is limited and the operator can read the gauge at close range.

  • Nominal dial size2.5 in
  • Mountinglower radial connection
  • Accuracy options listed on the product page1.6% or 2.5%, depending on configuration
  • Fill options listed on the product pageglycerin or silicone oil
  • Thread families listed on the product pageNPT, BSP, and metric options
  • Wetted-material options listed on the product pagebrass, SUS201, SUS304, or SUS316
  • Case-material options listed on the product pageSUS201 or SUS304
  • Ingress protection listed on the product pageIP54
  • Operating temperature listed on the product page-4°F to 140°F (-20°C to 60°C)
  • Maximum media temperature listed on the product page140°F (60°C)

Specify the measuring point before the gauge

Choose the pressure range around the actual operating condition, including startup, shutdown, pulsation, and foreseeable pressure peaks. The operating guidance for these gauges places normal pressure in the middle portion of the scale, typically between one-third and two-thirds of full scale. A snubber, restrictor, or remote mounting arrangement may still be needed when the system produces sharp spikes that a liquid fill cannot remove.

Match every process-contact material to the medium. Water, oil, compressed air, chemicals, and hydraulic fluid can require different Bourdon tube, socket, seal, and connection materials. A stainless steel case protects the movement from the surrounding environment; it does not prove that the wetted parts are suitable for a corrosive medium.

Specify the complete process connection: thread standard, nominal size, male or female form, sealing method, and connection position. A 1/4 NPT thread and a G 1/4 parallel thread are different connections even when their nominal sizes look similar. For panel installations, also provide the cutout, flange-hole pattern, rear clearance, and desired dial orientation.

Temperature affects both the gauge and the fill. The product pages list an ambient range of -4°F to 140°F (-20°C to 60°C) and a maximum media temperature of 140°F (60°C), but the final configuration must also account for heat transfer from the process, cold-start viscosity, and the response speed the application requires.

Send Your Operating Conditions

Where liquid-filled gauges earn their place

Pump discharge and suction points often combine equipment vibration with pressure ripple. A liquid-filled gauge reduces pointer oscillation so an operator can see the general operating pressure, while a properly selected snubber or other protection handles severe pulsation and spikes.

Compressors and pneumatic equipment can transmit cyclic pressure changes through the connection. Damping improves readability during operation, and a supported or remotely mounted connection can reduce mechanical load from the vibrating pipe or machine.

Hydraulic power units, presses, and mobile machinery create both vibration and fast pressure events. The gauge range must cover normal working pressure and anticipated peaks, and every valve, adapter, hose, and gauge in the measurement chain must have suitable pressure and material ratings.

Liquid-filled gauges also suit vibrating production equipment where a dry pointer continually moves. For strong oxidizers, oxygen, chlorine, flammable service, or other reactive media, specify the required cleaning, wetted materials, and an approved inert fill arrangement. A standard glycerin-filled configuration should not be ordered for those services without application review.

Discuss Your Application

Filled, calibrated, and checked before shipment

Hangzhou Dongya Instrument Co., Ltd. assembles the Bourdon tube, movement, dial, pointer, case, window, and seals before filling vibration-resistant gauges under vacuum. The documented process uses a vacuum of at least -0.09 MPa, leaves expansion space above the liquid, and rejects visible bubbles in the finished fill.

Calibration follows after the fill has stabilized. Indication is checked during increasing and decreasing pressure at no fewer than 0%, 20%, 50%, 75%, and 100% of full scale. The inspection records cover indication error, hysteresis, tap displacement, zero return, and smooth pointer travel. A sealing test applies 1.25 times full-scale pressure for five minutes and checks the connection, welds, and case for leakage or pressure decay.

Available order options include pressure range, units, dial markings, process thread, mounting direction, wetted materials, glycerin or silicone fill, customer logo, and requested inspection documents. Standard in-stock pressure gauges normally ship 1–2 business days after order confirmation; regular custom gauges have a 3–5 business-day reference lead time. Quantity, component availability, special materials, documentation, and process complexity determine the confirmed schedule.

Request a Quote

Request a quote

  • Phone: 008618968133688
  • Email: [email protected]
  • WhatsApp: 008618968133688
  • Address: Hangzhou Dongya Instrument New Plant Area, Zhougongwu, Yinhu Street, Fuyang District, Hangzhou City, Zhejiang Province (North side of National Highway 320)

Send the operating pressure, pressure unit, medium, temperature, dial size, mounting direction, process connection, quantity, and fill preference. Include any accuracy, dial artwork, logo, inspection record, or third-party report requirement before production planning.

WhatsApp QR Code WhatsApp Chat
+86-18968133688