Oxygen Cylinder Pressure Gauge China Professional Manufacturer

The oxygen cylinder pressure gauge produced by East Asia Meters strictly implements the medical grade oil-free degreasing process, ensuring absolute safety in use under hyperbaric oxygen environment through multiple precision ultrasonic cleaning. As a source physical manufacturing factory with more than thirty years of industry experience, we directly connect with global buyers, eliminate all trade intermediate links, and provide you with highly competitive direct supply prices and shorter delivery cycles.

40 to 150 mm Instrument outer diameter
1.6 or 2.5 Accuracy level
0 to 25 MPa Measuring range
HPb59 minus 1 brass Joint material
M14 by 1.5 Connecting thread
Black powder coated steel Shell Material
Phosphor bronze Bourdon tube Internal components
meets medical grade standards Oil-free treatment
oxygen cylinder pressure gauge

Oxygen Cylinder Pressure Gauge(images 2)

Medical-grade oil-free degreasing process

The product strictly follows the oxygen instrument manufacturing standards and passes four ultrasonic degreasing and cleaning processes to ensure that there is no oil residue inside. This fundamentally eliminates the risk of spontaneous combustion or explosion caused by contact between high-pressure oxygen and oil, and ensures the extreme safety of medical and industrial gas.

Oxygen Cylinder Pressure Gauge(images 3)

Reinforced phosphor bronze Bourdon tube

The core pressure sensing element is made of high-quality phosphor bronze, which has excellent elastic modulus and fatigue resistance. After 10,000 full-scale cyclic pressure tests, the instrument can still maintain the initial measurement accuracy, effectively extending the service life of the product in frequent filling environments.

Oxygen Cylinder Pressure Gauge(images 4)

Weather-resistant black steel housing

The housing is made of high-strength steel and has been electrostatically powder-coated for excellent corrosion and impact resistance. Whether on an outdoor welding site or in a hospital ward, the case provides strong protection for the precision movement inside, reducing damage from drops.

Oxygen Cylinder Pressure Gauge(images 5)

Clear international warning signs

The dial is prominently printed with a striking red no-oil sign, which meets international traffic safety warning standards. Even at operation sites with low light, staff can clearly distinguish the purpose of the instrument, effectively preventing the mixing of oxygen meters and ordinary gas meters.

Oxygen Cylinder Pressure Gauge(images 6)

Precision gear-rotating movement

The internal movement is machined by automated CNC machine tools, and the gear meshing tolerance is controlled within a very small range. This ensures smooth and non-stuttering pointer operation, effectively reduces back-difference and value indication errors, and provides gas regulators with an accurate reading reference.

Oxygen Cylinder Pressure Gauge(images 7)

High performance sealed connection design

The joint thread is strictly gauge tested to ensure perfect match with the gas cylinder pressure reducing valve. In conjunction with the factory’s 100% factory airtightness test, it solves the common interface micro-air leakage problem in the industry and ensures the overall integrity of the high-pressure gas transmission system.

Key technology itemsoxygen cylinder pressure gauge detailed description
Specifications and ModelsHangzhou Dongya Instrument Y Series Oxygen Gauge
nominal diameter40mm, 50mm, 60mm, 100mm, 150mm
Accuracy level1.6% or 2.5% of the full range
Pressure rangeCommonly used ranges are 0-25 MPa, 0-40 MPa, or custom ranges.
Operating ambient temperature-40 degrees Celsius to +70 degrees Celsius
Sensitive component materialPhosphor bronze QSn6.5-0.1
Instrument connector materialHPb59-1 copper alloy
Dial window materialPolycarbonate or ordinary flat glass

The oxygen cylinder pressure gauge produced by East Asian meters has significant advantages in material purity and safety compliance compared to similar products on the market. We utilize our own automated cleaning production line to ensure that every meter meets stringent oil pollution control standards, providing high-reliability monitoring solutions for B2B customers around the world.

oxygen cylinder pressure gauge

Oxygen Cylinder Pressure Gauge(images 9)

Eliminate the fire hazard in high-pressure environments

East Asia Instruments solves the problem of incomplete manual cleaning by ordinary manufacturers. We use fully automatic ultrasonic degreasing lines to ensure that the grease residue inside the meter is far below the industry safety threshold, preventing chemical fires in high-pressure oxygen environments.
Oxygen Cylinder Pressure Gauge(images 10)

Solve the difficulty of pointer jitter reading

In response to the characteristics of cylinder pressure fluctuations, Hangzhou East Asia Instrument has optimized the movement dynamic balance design. We have solved the pain point of traditional oxygen meters when the needle swings violently when the gas source is unstable, making it difficult to read accurately and prone to bending and damage.
Oxygen Cylinder Pressure Gauge(images 11)

Reduce long-term maintenance and replacement costs

Hangzhou East Asia Instruments uses high-strength copper alloy joints. This solves the pain point of ordinary pressure gauge joints that are prone to thread wear and deformation when frequently changing gas cylinders, and significantly improves the service life and connection reliability of the instrument.

Industrial gas filling manufacturer

Suitable for factories that need to handle a large number of oxygen cylinder filling businesses every day. The high-durability pressure gauges provided by Hangzhou East Asia Instruments can withstand frequent pressure fluctuations, greatly reducing the equipment downtime and maintenance time caused by instrument damage.

Oxygen cylinder pressure gauge applicable to people

Medical device distributors

meet the extremely high safety requirements for gas monitoring in medical scenarios such as hospital wards and hyperbaric oxygen chambers. When purchasing, this group places greater emphasis on the oil-free certification and medical-grade manufacturing qualifications of Hangzhou East Asia Instruments to ensure the safety of clinical oxygen use.

Oxygen cylinder pressure gauge applicable to people

Welding and cutting equipment supplier

Applicable to suppliers who provide oxyacetylene cutting systems for shipyards and steel structure plants. The Hangzhou East Asia Instrument’s rugged steel shell design is well-suited to harsh industrial construction environments and can effectively cope with collisions and metal dust pollution.

Oxygen cylinder pressure gauge applicable to people

International Gas Trading Company

standard gas equipment distribution for the global market. Hangzhou East Asia Instruments supports the customization of various pressure units and thread specifications, assisting traders to quickly meet the access standards of different countries and regions, and enhance their competitiveness in the global supply chain.

Oxygen cylinder pressure gauge applicable to people
Oxygen Cylinder Pressure Gauge(images 16)

Before installing to the oxygen cylinder system, it must be confirmed that all connecting tools and hands are free of any oil contamination. The use of oil-containing sealing strips is strictly prohibited to prevent dangerous reactions.

Oxygen Cylinder Pressure Gauge(images 17)

A wrench should be used to fix the hexagonal position of the joint during installation. Tightening the instrument by hand rotating the case is prohibited, and the instrument dial should be kept in a vertically upward position.

Oxygen Cylinder Pressure Gauge(images 18)

When opening the cylinder main valve, be sure to act slowly to prevent the instantaneous high-pressure airflow impact from causing the instrument pointer to bend or the Bourdon tube to permanently deform, and ensure that the measurement data is true.

Oxygen Cylinder Pressure Gauge(images 19)

It is recommended to approve the accuracy of the instrument every six months. If the pointer cannot be reset to zero or the housing is significantly deformed, it must be stopped immediately and replaced by professionals.

certificate

factory

Welcome to our Frequently Asked Questions page. We have compiled answers to common questions you may have, hoping to provide you with clear and quick solutions. If you cannot find the information you need here, please feel free to contact our customer support team.

Q: What is the difference between oxygen meter and ordinary pressure gauge in production?
A: All parts of the oxygen meter must be strictly degreased and cleaned before assembly to ensure that there is no grease residue, which is an operation that is not required for ordinary pressure meters.
Q: Can this watch be customized with different threads as required?
A: As the source factory, East Asia Meter supports thread customization of M14, G1/4, NPT1/4 and other specifications to meet global market demand.
Q: Why do oxygen meters usually have red markings on the dial?
A: That is to warn operators that exposure to grease is strictly prohibited. This is a mandatory requirement of the safety operating procedures, and the red logo can serve as a significant reminder.
Q: Can I continue using it if the pointer does not point to the zero position?
Answer: No. The pointer does not return to zero, which means that the internal elastic element may have produced plastic deformation, and continued use will lead to measurement errors and even air leakage hazards.
Q: Are there any relevant quality certifications for East Asia Instruments products?
A: Our factory has passed ISO9001 quality management system certification, and the production of products strictly implements the national pressure instrument manufacturing standards and oil-free standards.
Q: Can you take large volume OEM custom orders?
A: Yes. With 10 production lines and more than 300 production equipment, we have strong mass production capabilities and support customized production according to customer brands.
E-mail*
Number
Country
Name
Your Question
Submitting!
Success!
Submission failed! Please try again later!
Email format error!
Format error!

Oxygen Cylinder Pressure Gauge China Professional Manufacturer

The oxygen cylinder pressure gauge produced by East Asia Meters strictly implements the medical grade oil-free degreasing process, ensuring absolute safety in use under hyperbaric oxygen environment through multiple precision ultrasonic cleaning. As a source physical manufacturing factory with more than thirty years of industry experience, we directly connect with global buyers, eliminate all trade intermediate links, and provide you with highly competitive direct supply prices and shorter delivery cycles.

oxygen cylinder pressure gauge

Oxygen Cylinder Pressure Gauge(images 23)

The product strictly follows the oxygen instrument manufacturing standards and passes four ultrasonic degreasing and cleaning processes to ensure that there is no oil residue inside. This fundamentally eliminates the risk of spontaneous combustion or explosion caused by contact between high-pressure oxygen and oil, and ensures the extreme safety of medical and industrial gas.

Oxygen Cylinder Pressure Gauge(images 24)

The core pressure sensing element is made of high-quality phosphor bronze, which has excellent elastic modulus and fatigue resistance. After 10,000 full-scale cyclic pressure tests, the instrument can still maintain the initial measurement accuracy, effectively extending the service life of the product in frequent filling environments.

Oxygen Cylinder Pressure Gauge(images 25)

The housing is made of high-strength steel and has been electrostatically powder-coated for excellent corrosion and impact resistance. Whether on an outdoor welding site or in a hospital ward, the case provides strong protection for the precision movement inside, reducing damage from drops.

Oxygen Cylinder Pressure Gauge(images 26)

The dial is prominently printed with a striking red no-oil sign, which meets international traffic safety warning standards. Even at operation sites with low light, staff can clearly distinguish the purpose of the instrument, effectively preventing the mixing of oxygen meters and ordinary gas meters.

Oxygen Cylinder Pressure Gauge(images 27)

The internal movement is machined by automated CNC machine tools, and the gear meshing tolerance is controlled within a very small range. This ensures smooth and non-stuttering pointer operation, effectively reduces back-difference and value indication errors, and provides gas regulators with an accurate reading reference.

Oxygen Cylinder Pressure Gauge(images 28)

The joint thread is strictly gauge tested to ensure perfect match with the gas cylinder pressure reducing valve. In conjunction with the factory’s 100% factory airtightness test, it solves the common interface micro-air leakage problem in the industry and ensures the overall integrity of the high-pressure gas transmission system.

Key technology itemsoxygen cylinder pressure gauge detailed description
Specifications and ModelsHangzhou Dongya Instrument Y Series Oxygen Gauge
nominal diameter40mm, 50mm, 60mm, 100mm, 150mm
Accuracy level1.6% or 2.5% of the full range
Pressure rangeCommonly used ranges are 0-25 MPa, 0-40 MPa, or custom ranges.
Operating ambient temperature-40 degrees Celsius to +70 degrees Celsius
Sensitive component materialPhosphor bronze QSn6.5-0.1
Instrument connector materialHPb59-1 copper alloy
Dial window materialPolycarbonate or ordinary flat glass

oxygen cylinder pressure gauge comparison point

oxygen cylinder pressure gauge
Oxygen Cylinder Pressure Gauge(images 30)
Eliminate the fire hazard in high-pressure environments
East Asia Instruments solves the problem of incomplete manual cleaning by ordinary manufacturers. We use fully automatic ultrasonic degreasing lines to ensure that the grease residue inside the meter is far below the industry safety threshold, preventing chemical fires in high-pressure oxygen environments.
Oxygen Cylinder Pressure Gauge(images 31)
Solve the difficulty of pointer jitter reading
In response to the characteristics of cylinder pressure fluctuations, Hangzhou East Asia Instrument has optimized the movement dynamic balance design. We have solved the pain point of traditional oxygen meters when the needle swings violently when the gas source is unstable, making it difficult to read accurately and prone to bending and damage.
Oxygen Cylinder Pressure Gauge(images 32)
Reduce long-term maintenance and replacement costs
Hangzhou East Asia Instruments uses high-strength copper alloy joints. This solves the pain point of ordinary pressure gauge joints that are prone to thread wear and deformation when frequently changing gas cylinders, and significantly improves the service life and connection reliability of the instrument.

Industrial gas filling manufacturer

Suitable for factories that need to handle a large number of oxygen cylinder filling businesses every day. The high-durability pressure gauges provided by Hangzhou East Asia Instruments can withstand frequent pressure fluctuations, greatly reducing the equipment downtime and maintenance time caused by instrument damage.

Oxygen cylinder pressure gauge applicable to people

Medical device distributors

meet the extremely high safety requirements for gas monitoring in medical scenarios such as hospital wards and hyperbaric oxygen chambers. When purchasing, this group places greater emphasis on the oil-free certification and medical-grade manufacturing qualifications of Hangzhou East Asia Instruments to ensure the safety of clinical oxygen use.

Oxygen cylinder pressure gauge applicable to people

Welding and cutting equipment supplier

Applicable to suppliers who provide oxyacetylene cutting systems for shipyards and steel structure plants. The Hangzhou East Asia Instrument’s rugged steel shell design is well-suited to harsh industrial construction environments and can effectively cope with collisions and metal dust pollution.

Oxygen cylinder pressure gauge applicable to people

International Gas Trading Company

standard gas equipment distribution for the global market. Hangzhou East Asia Instruments supports the customization of various pressure units and thread specifications, assisting traders to quickly meet the access standards of different countries and regions, and enhance their competitiveness in the global supply chain.

Oxygen cylinder pressure gauge applicable to people
Oxygen Cylinder Pressure Gauge(images 37)

Before installing to the oxygen cylinder system, it must be confirmed that all connecting tools and hands are free of any oil contamination. The use of oil-containing sealing strips is strictly prohibited to prevent dangerous reactions.

Oxygen Cylinder Pressure Gauge(images 38)

A wrench should be used to fix the hexagonal position of the joint during installation. Tightening the instrument by hand rotating the case is prohibited, and the instrument dial should be kept in a vertically upward position.

Oxygen Cylinder Pressure Gauge(images 39)

When opening the cylinder main valve, be sure to act slowly to prevent the instantaneous high-pressure airflow impact from causing the instrument pointer to bend or the Bourdon tube to permanently deform, and ensure that the measurement data is true.

Oxygen Cylinder Pressure Gauge(images 40)

It is recommended to approve the accuracy of the instrument every six months. If the pointer cannot be reset to zero or the housing is significantly deformed, it must be stopped immediately and replaced by professionals.

Know Us and Contact Us

*
Submitting!
Success!
Submission failed! Please try again later!
Email format error!
Format error!
FAQ

FAQ

Q: What is the difference between oxygen meter and ordinary pressure gauge in production?
A: All parts of the oxygen meter must be strictly degreased and cleaned before assembly to ensure that there is no grease residue, which is an operation that is not required for ordinary pressure meters.
Q: Can this watch be customized with different threads as required?
A: As the source factory, East Asia Meter supports thread customization of M14, G1/4, NPT1/4 and other specifications to meet global market demand.
Q: Why do oxygen meters usually have red markings on the dial?
A: That is to warn operators that exposure to grease is strictly prohibited. This is a mandatory requirement of the safety operating procedures, and the red logo can serve as a significant reminder.
Q: Can I continue using it if the pointer does not point to the zero position?
Answer: No. The pointer does not return to zero, which means that the internal elastic element may have produced plastic deformation, and continued use will lead to measurement errors and even air leakage hazards.
Q: Are there any relevant quality certifications for East Asia Instruments products?
A: Our factory has passed ISO9001 quality management system certification, and the production of products strictly implements the national pressure instrument manufacturing standards and oil-free standards.
Q: Can you take large volume OEM custom orders?
A: Yes. With 10 production lines and more than 300 production equipment, we have strong mass production capabilities and support customized production according to customer brands.
certificate