Panel Mount Pressure Gauges | dypressuregauge

panel mount pressure gauges dypressuregauge

Pressure indication built into your equipment panel

Choose a 60 mm or 100 mm front-flange analog gauge for a new machine panel or a replacement opening. Hangzhou Dongya Instrument Co., Ltd. can match the dial, pressure range, process connection, materials, and panel interface to the approved order specification.

A pressure gauge designed around the panel

A panel-mounted mechanical gauge keeps the dial on the operator side while the pressure connection and piping remain behind the panel. The front flange fixes the case at the opening, and the process connection carries pressure to the Bourdon tube inside the gauge. The tube’s movement is transferred through the mechanism to the pointer for a local reading.

Mounting style and measuring specification are separate decisions. A front flange can solve access and layout requirements, but it does not determine the pressure range, process compatibility, accuracy, thread, or sealing method. Those fields still have to match the pressure point.

The Y-60ZT and Y-100ZT shown here use round analog dials and three-hole front flanges. Their different nominal dial sizes let designers balance a compact panel layout against easier reading from farther away.

The panel drawing comes before the cutout

A 60 mm or 100 mm dial designation does not define the panel opening. Nominal dial size, case diameter, flange diameter, mounting-hole circle, rear depth, and process-connection position are different dimensions.

For a new panel, use the approved model drawing to place the center opening and flange holes. Also reserve space behind the panel for the case, rear connection, fitting, tubing bend, wrench access, and future removal.

For a replacement, record the existing gauge from both the front and the side. Measure the flange outside diameter, case diameter, cutout, hole spacing, depth behind the panel, and thread. Measuring only the clear window or ordering by a “2-inch” or “4-inch” description can leave the new flange unable to cover the opening or align with the mounting holes.

Send Us Your Panel Dimensions

Panel mount gauge models

Y-100ZT pressure gauge with silver front flange and 0–1.6 MPa dual-scale dial

Standard Pressure Gauge Y-100ZT

The Y-100ZT is the larger of the two specified front-flange models. Its nominal 100 mm dial provides more room for scale marks and labels, making it the stronger starting point when the reading distance matters and the panel has enough space. The pictured configuration has a 0–1.6 MPa inner scale and an approximately 0–230 psi outer scale. Available pressure range, connection, materials, accuracy class, flange dimensions, and cutout must be confirmed for the ordered configuration.

  • ModelY-100ZT
  • Nominal dial size100 mm (about 4 in)
  • DisplayAnalog pointer
  • Dial units shownMPa and psi
  • Range shown in image0–1.6 MPa / approximately 0–230 psi
  • Panel interface shownThree-hole front flange
  • Process connectionConfirm thread and rear-connection dimensions on the order drawing
Y-60ZT compact pressure gauge with front flange and 0–2.5 MPa dual-scale dial

Standard Pressure Gauge Y-60ZT

The Y-60ZT places a mechanical dial in a smaller panel envelope. It suits equipment viewed at close range when controls, indicators, and labels must share limited front-panel space. The pictured configuration has a 0–2.5 MPa inner scale and a 0–350 psi outer scale. Confirm the required accuracy class on the quotation and approved specification rather than assuming it from the model name.

  • ModelY-60ZT
  • Nominal dial size60 mm (about 2.4 in)
  • DisplayAnalog pointer
  • Dial units shownMPa and psi
  • Range shown in image0–2.5 MPa / 0–350 psi
  • Panel interface shownThree-hole front flange
  • Process connectionConfirm thread and rear-connection dimensions on the order drawing

Choose 60 mm or 100 mm by the way the panel is used

Dial size affects both the space used on the panel and how easily an operator can distinguish scale marks. The 60 mm model leaves more room for neighboring controls. The 100 mm model gives the scale more area and is generally easier to read when the operator stands farther from the panel or needs clearer graduation spacing.

Selection conditionY-60ZTY-100ZT
Front-panel spaceBetter starting point for a compact layoutRequires a larger front-panel envelope
Typical viewing conditionClose-range equipment viewingLonger viewing distance or a preference for a larger scale
Replacement workMatch the existing 60 mm-class drawing and openingMatch the existing 100 mm-class drawing and opening
Mounting appearance shownThree-hole front flangeThree-hole front flange
Final decision requiresApproved cutout, hole circle, depth, thread, range, accuracy, and material specificationApproved cutout, hole circle, depth, thread, range, accuracy, and material specification

A larger face does not compensate for the wrong pressure range, and a smaller face is not automatically suitable for a crowded panel. Scale density, units, lighting, viewing angle, and normal reading distance belong in the same decision as the available panel area.

Complete the measurement specification

Panel mounting defines where the gauge sits. The process conditions define what the gauge must measure and which configuration can do it.

SpecificationWhat to provideWhy it changes the gauge
PressureNormal pressure, maximum pressure, required range, and unitsEstablishes the scale and operating region
Process mediumGas or liquid name, concentration when relevant, and process temperatureDetermines wetted-material compatibility and whether isolation is required
Pressure behaviorSteady service, vibration, pulsation, or pressure spikesMay call for liquid filling, restriction, or another protective arrangement
ConnectionComplete thread standard, nominal size, male/female form, and sealing methodPrevents mismatched threads and defines the rear piping interface
PanelCutout, flange envelope, hole circle, panel thickness, and available rear depthDetermines whether the case and mounting hardware fit
ReadingDial size, range, units, color zones, language, and logoDefines what the operator sees
OrderQuantity, required certificates or reports, packaging, and delivery destinationDefines production, documentation, and quotation scope

For corrosive, viscous, crystallizing, solid-bearing, or high-temperature media, include the full process description. The correct solution may require different wetted materials or a diaphragm seal rather than a standard direct-contact gauge.

Build My Gauge Specification

Install the flange and pressure line as separate load paths

Secure the gauge with the specified flange hardware before connecting the pressure line. Tighten the flange evenly so the case is held without distortion. Over-tightening can load the case or window and interfere with pointer movement.

Align and support the rear pressure line independently. Apply installation torque only to the wrench flats on the pressure connection; rotating the case to pull the thread into alignment can transmit stress to the socket, case, and movement.

Keep working clearance behind the panel for the fitting, tubing bend, wrench, vent or relief features, and gauge removal. A visually clean front panel can still be unserviceable when the rear connection is pressed against cabinet hardware.

After installation, check the pointer at zero, flange clamping, connection leakage, free pointer travel, and interference with nearby components before placing the equipment in service.

Built and checked by a pressure-instrument manufacturer

Established in 2002, Hangzhou Dongya Instrument Co., Ltd. manufactures pressure gauges and supplies pressure transmitters, pressure controllers, and thermometers.

Pressure-gauge production covers incoming inspection, Bourdon-tube assembly, movement installation, dial and pointer assembly, pressure adjustment, case sealing, calibration, final inspection, labeling, and packing. Liquid-filled versions add filling and a second calibration after the fill has stabilized.

Finished gauges are checked for appearance, zero position, indication, hysteresis, tap response, pointer movement, and leakage. The factory procedure uses rising and falling pressure at no fewer than five points: 0%, 20%, 50%, 75%, and 100% of full scale. Its leakage check applies 1.25 times full scale for five minutes.

Each batch receives factory inspection, and an internal inspection record can be provided. A third-party calibration or test report is a separate service; state the report type and issuing-body requirement before production so the cost, sample quantity, and schedule can be included in the order.

Discuss Inspection Documents

Request a panel-mount gauge quote

Send the model you are considering, or attach the existing gauge nameplate and front/side dimensions for a replacement. Include the pressure range and units, process medium and temperature, thread, panel opening, rear clearance, quantity, and required documents. We will review the technical conditions before confirming the product configuration, price, and delivery schedule.

Contact Hangzhou Dongya Instrument Co., Ltd.

  • Phone / WhatsApp: 008618968133688
  • Email: [email protected]
  • Address: Hangzhou Dongya Instrument New Plant Area, Zhougongwu, Yinhu Street, Fuyang District, Hangzhou City, Zhejiang Province (North side of National Highway 320)
Browse All Products

Inquiry form

WhatsApp QR Code WhatsApp Chat
+86-18968133688