Direct Pipe Or Equipment Mounting
Y-60: radial lower M14×1.5 connection. Use this layout when the dial can be read above the process port and no front-panel flange is required.
PRODUCT SECONDARY CATEGORY PAGE
Choose dry Bourdon-tube Standard Pressure Gauge models for non-corrosive liquids, gases and steam. Hangzhou Dongya Instrument supplies 60 mm and 100 mm radial or panel-mount versions with configurable ranges, threads and dial markings.
RANGE · DIAL · ACCURACY
Which range and dial size provide useful resolution without routine over-range loading?
| Option | Verified Specification | Impact | Best Fit |
|---|---|---|---|
| Y-60 / Y-60ZT | 60 mm dial, class 2.5 | Compact and economical; lower reading resolution | Tight layouts and close-range viewing |
| Y-100ZT | 100 mm dial, class 1.6 | Easier reading and closer accuracy; larger panel space | Operator panels and longer viewing distance |
| Range Selection | 0–0.1 MPa to 0–60 MPa options by model | Too wide reduces resolution; too narrow raises over-range risk | Steady pressure at 25–75% FS; pulsating pressure at no more than 50% FS |
MOUNTING · CONNECTION FIT
Does the gauge mount directly on piping or through an equipment panel?
Y-60: radial lower M14×1.5 connection. Use this layout when the dial can be read above the process port and no front-panel flange is required.
Y-60ZT: center-back M14×1.5 with panel flange. Y-100ZT: center-back M20×1.5 with panel flange and a larger dial.
CATEGORY INTRODUCTION & BUYER PAIN POINTS
Standard pressure gauges provide local indication for general industrial equipment when the medium is compatible with steel and copper-alloy wetted parts.
Use these Y-series models on pumps, compressors, air systems, utility lines and other equipment handling non-explosive, non-crystallizing and non-solidifying liquid, gas or steam that does not corrode steel or copper alloys.
A range that is too wide hides small changes, while routine over-range shortens movement life. A mismatched M14×1.5 or M20×1.5 connection, or the wrong radial versus panel layout, can force adapters, rework or an unreadable viewing angle. Factory inspection covers appearance, zero, indication, sealing and a 1.25×FS five-minute pressure test.
PRODUCT REQUIREMENTS FOR THIS DUTY
Define pressure behavior, medium compatibility, mechanical fit and purchasing conditions before selecting a model.
Positive-pressure options span 0–0.1 MPa to 0–60 MPa. Keep steady pressure at 25–75% FS or pulsating pressure at no more than 50% FS. The 60 mm models are class 2.5; Y-100ZT is class 1.6.
Use only with non-explosive, non-crystallizing and non-solidifying media compatible with steel and copper alloys. Request a compatible alternative for corrosive, viscous or sanitary service.
Y-60: radial M14×1.5. Y-60ZT: center-back panel M14×1.5. Y-100ZT: center-back panel M20×1.5. Confirm thread, cut-out, rear clearance and viewing direction.
State model, range, thread, quantity, destination and documents. Stocked standard gauges normally ship in 1–2 business days; custom configurations normally require 3–5 business days.
RECOMMENDED PRODUCTS / MODELS
The three dry Y-series models share a general Bourdon-tube principle but differ in dial size, accuracy class, thread and mounting direction. Choose installation geometry first, then range and readability.

Panel-mounted local indication where readability and class 1.6 accuracy matter.

Compact panel-mounted indication for compatible general industrial media.

Direct radial mounting on pumps, compressors, utility lines and equipment.
PRODUCTION & DELIVERY
Prices are quoted by model, range, thread, dial, quantity and destination. Default quantities below are planning values and are confirmed in the quotation.
1 paid sample, quoted separately. A stocked standard configuration normally ships in 1–2 business days; custom samples normally require 3–5 business days after specification confirmation.
10–99 units per model. Pricing varies by range, thread, dial and quantity; outgoing inspection and shock-resistant packing are included.
100+ units per model for volume pricing. Custom dial or private-label work uses a default MOQ of 100 units per model, with schedule and tooling confirmed in the quotation.
Standard gauges genuinely in stock normally ship in 1–2 business days. Custom range, thread, dial or logo configurations normally require 3–5 business days after order and drawing confirmation.
EXW, FOB or CIF terms can be quoted. Express courier, air freight and sea freight are selected by carton volume, urgency and destination import requirements.
Commercial invoice, packing list and product certificate are available with shipment. Internal inspection records and third-party testing can be requested before order confirmation; added cost and lead time are quoted separately.
APPLICATION PAIN POINTS & SOLUTIONS
Use dial size, accuracy, connection and mounting geometry to resolve the most common selection conflicts.
Specification response: A 100 mm dial improves viewing distance and scale resolution, while class 1.6 accuracy supports closer reading than the 60 mm class 2.5 models. The M20×1.5 center-back connection and flange suit front-panel installation; allow the larger panel cut-out and rear clearance.
Specification response: The 60 mm face and center-back M14×1.5 connection reduce the panel footprint while retaining a front-facing display. The trade-off is class 2.5 accuracy and lower readability than the 100 mm model.
Specification response: The radial lower M14×1.5 connection mounts directly to suitable piping or equipment without a front-panel flange. It is compact and economical, but the installer must provide a readable viewing angle and avoid using the case as installation leverage.
SELECTION COMPARISON
Both layouts serve compatible general industrial media; the key decision is how the dial is installed and viewed.
| Model / Layout | Best Environment | Key Advantage | Limit / Trade-Off |
|---|---|---|---|
| Y-60 · Radial | Exposed local pipe or equipment mounting | Compact 60 mm layout with M14×1.5 lower connection | Class 2.5 accuracy and shorter viewing distance; no panel flange |
| Y-60ZT / Y-100ZT · Panel | Front panels and equipment consoles | Center-back connection and flange; choose compact 60 mm or readable 100 mm | Requires panel cut-out and rear clearance; Y-100ZT uses M20×1.5 |
NON-STANDARD CUSTOM CHANNEL
Include pressure range, medium, thread, mounting direction, dial markings and quantity. Uploaded files are used only to prepare a quotation and technical review.
PDF, DWG, DXF, STEP, STP, JPG, JPEG or PNG, up to 10 MB. Final feasibility, sample cost, MOQ and documentation are confirmed in the quotation.
ACCESSORIES / CONSUMABLES
Choose each accessory by thread, process compatibility and the actual pressure behavior.
Compatibility: Use with a matching M14×1.5 or M20×1.5 connection and medium-compatible brass or stainless-steel material. Use: Reduces pressure pulsation reaching the gauge movement. Service: Inspect during each maintenance interval and replace if restricted, leaking or damaged.
Compatibility: Select the same process thread and a valve material compatible with the measured medium. Use: Allows the gauge to be isolated for replacement or service. Service: Exercise and inspect during planned maintenance; replace if sealing or operation deteriorates.
Compatibility: Flange and bracket dimensions must match Y-60ZT or Y-100ZT; adapters must match both gauge and process threads. Use: Supports secure panel mounting or a controlled thread transition. Service: Reuse only when threads, sealing faces and mounting holes remain undamaged.
FAQ
Use these answers to narrow the range, mounting and commercial route before requesting a final quotation.
Y-60 is a 60 mm radial lower-mount gauge with an M14×1.5 connection. Y-60ZT is a 60 mm center-back panel-flange gauge with M14×1.5. Y-100ZT adds a 100 mm dial, class 1.6 accuracy and an M20×1.5 center-back connection.
For steady service, choose a full-scale range that places normal pressure at about 25–75% of the dial. For pulsating service, keep normal pressure at or below 50% of full scale. A wider range protects the movement but reduces reading resolution.
These dry general-service gauges are intended for non-explosive, non-crystallizing and non-solidifying liquids, gases or steam that do not corrode steel or copper-alloy wetted parts. Request a compatible alternative for corrosive, viscous or sanitary media.
One paid sample is available by quotation. The default MOQ is 10 units per model for standard configurations and 100 units per model for custom dial or private-label work. Stocked standard gauges normally ship in 1–2 business days; made-to-order configurations normally require 3–5 business days after order confirmation.
Yes. Range, process thread, dial markings, logo and selected mounting details can be reviewed from a drawing or specification. Final feasibility, sample cost, MOQ and documentation are confirmed in the quotation before production.
REQUEST A TECHNICAL QUOTE
Send the model, range, thread, quantity and delivery destination. Add the medium and mounting layout when you need an engineering check.